top of page

190 Storm

190 Storm

Download Detailed Brochure

190 Storm

Built for extreme-use applications in the weighing industry, the 190 STORM’s IP69K-rated polycarbonate enclosure withstands high-temperature (up to 176º F / 80º C), high-pressure wash downs (1450 PSI). 


The 190 STORM features capacitive touch keys, 1-inch-high clearly visible LCD digits, built-in RS232 communications port, and versatile power options: AC, DC, and rechargeable battery. The 190 STORM’s bright, vivid display changes color automatically as the pre-assigned target weights are reached. The operator knows immediately when they’ve reached the acceptable weight range based on the amber, green, or red color changes for UNDER, ACCEPT, or OVER weights. NTEP, OIML, and Measurement Canada.

Features

  • 1 RS232 Serial Port

  • 1-in-high LCD

  • Capacitive Touch Keys

  • ColorZONE Checkweighing

  • IP69K-Rated Washdown

  • NTEP Legal for Trade

  • OIML Certified

  • Ultra-Tough Polycarbonate Enclosure

Specifications

Power Requirements: 100 to 240 VAC (50/60 Hz) at 0.4A Max. / 190DC: 10.5 to 30 VDC 1.0A Max.
Enclosure Type: Polycarbonate and ABS enclosure, IP69K-rated wall or desk-mount
Enclosure Size: 9.4 in W x 6.4 in H x 3.7 in D / 239 mm W x 163 mm H x 93 mm D
Display: Six digit, seven segment, 1.0 in high backlit LCD
Transducer Excitation: 5.18 VDC
Signal Input Range: 0.5 mV min. to 40 mV max. (with dead load boost)
Number of Load Cells: 6 each, 350 OHM minimum resistance
Load Cell Cable Length: 1500 feet maximum / 30 feet maximum without sense lines (Consult factory for other requirements
Division Value: 1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001 commercial / 0 to 99, non-commercial
Sensitivity (NON-COMMERCIAL): 0.15 uV/e
Sensitivity (COMMERCIAL): 100 to 10,000 (Class III/IIIL/IIIHD)
Internal Resolution: 1 part in 16,777,216
Tare Capacity: Scale Capacity
Sample Rate: 1 to 100 samples per second, selectable
Auto Zero Range: 0.5 or 1 through 9 divisions
Weighing Units: Pounds, Ounces, Kilograms, Grams
Keypad: Color Coded Capacitive Touch type, 7 keys
Standard I/O: 1 bi-directional RS232 serial
NTEP Approval: 10-084
OIML: R76/1992-DK3-11.05
Measurement Canada: AM-5804
Enclosure IP Rating: IP69K
Operating Environment: Temperature: 14 to 104 ºF (-10 to +40 ºC) / Humidity: 90% non-condensing (maximum)
Optional Battery Charge Time: 6 hours
Optional Rechargeable Battery Continuous Operation Run Times: Running single load cell - 92 hours with NO backlight / 83 hours with BLUE backlight / 48 hours with RED backlight / 48 hours with PINK backlight / 45 hours with GREEN backlight / 41 hours with YELLOW backlight / Battery life will be extended with SLEEP and AUTO-OFF operation set