top of page

882IS Intrinsically Safe Digital Weight Indicator

882IS Intrinsically Safe Digital Weight Indicator

Download Detailed Brochure

SAFE, ACCURATE WEIGHT READINGS IN HAZARDOUS LOCATIONS 


The intrinsically safe, auto-ranging power supply enables wiring to a single AC conduit line and seal from the safe area. An FM approved, rechargeable battery is also available for isolated power or movable applications. The 882IS utilizes a backlit LCD display to maintain brilliant visibility for user-friendly operation, even in dimly lit areas. Its stainless steel enclosure provides superior protection from the elements. 


ENHANCED CONNECTIVITY 


Expand flexibility with an optional safe area I/O Module, featuring a serial port, Ethernet TCP/IP and optional analog output or fieldbus cards for communication with printers, computers and other peripherals. A duplex fiber-optic port allows for electrically-isolated communication with the I/O Module. To complete the IS entity approved system, Rice Lake offers FM/ATEX-approved load cells and junction boxes that interface with the 882IS indicator.

Features

  • 0.8in, seven-digit, seven-segment LCD display with white LED backlight

  • Stainless steel IP66 enclosure

  • T4 temperature rating

  • Battery life display icon

  • Excitation for four 350-ohm or eight 700-ohm load cells

  • Tilt stand

  • Numeric keypad (882IS Plus only)

  • Duplex fiber optic interface

  • Power ON/OFF; battery save mode

  • Configurable local/remote mode

  • I/O module option: one serial port, optional analog output, optional fieldbus cards, Ethernet TCP/IP

  • Time & date (requires I/O module)

  • Setpoint functionality with remote indicator

  • FM Entity Approved for use in hazardous locations per Rice Lake Weighing Systems control drawing file number 180948

Specifications

Load Cell Excitation:
3.0 VDC at 87.5 Ω, 4.6 VDC at 700 Ω

Load Cell Current:
34 mA (4 x 350 Ω load cells) or (8 x 700 Ω load cells)

Load Cell Cabling:
Four and six-wire with remote sensing (recommended)

Analog Signal Input Range:
0.6 mV/V - 4.0 mV/V

Analog Signal Sensitivity:
0.2 μV/graduation minimum
1.5 μV/graduation recommended

Conversion Rate:
60 updates/second

Resolution:
10,000 displayed graduations (NTEP Certified),
1,000,000 expanded
The maximum number of allowed graduations will vary by application

Display Increments:
1, 2, 5

Display:
Seven-digit, seven-segment LCD display 121 x 24 dot
matrix messaging area with white LED backlight

Decimal Point:
Configurable with dead zeros

Unit Switching:
Configurable for two units of measurement with front panel operation with conversion for tare and setpoint values

Front Panel Control Switches:
882IS:
Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop
882IS Plus: Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad

Front Panel:
Ten-button plus power button flat membrane panel

Front Panel Annunciators:
Center Zero, Gross, Net, Motion, lb, kg, oz, g

Motion Band:
Configurable to ± 1 or ± 3 graduations, 1 second delay (or Off)

Power Input:
5.8-7.9 VDC,100-175 mA
Maximum power consumption 0.25 watts

Operating Temperature:
14° F to 104° F (-10° C to 40° C) legal

Electrical Operating Temperature:
14° F to 104° F (-10° C to 40° C) legal

Rating/Material:
Stainless steel IP66 enclosure

Optional Battery:
Operating times: 4 x 350 Ω = 60 hrs.
1 x 350 Ω = 80-100 hrs. Charging times: 8-10 hrs

Weight:
6.1 lb (2.8 kg)

Warranty:
One-year limited warranty

Intrinsic Safety:
FM/cFM:
Class I,II,III, Division 1, Groups ABCDEFG T4
Class I, Zone 0 AEx/Ex ia IIC T4 Ga
Zone 20 AEx/Ex ia IIIC T135°C Da
Ta = -10°C to +40°C (14°F to 104°F)
ATEX/IECEx:
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T135°C Da

Approvals:
UL/cUL Listed*
FM Entity
ATEX
IECEx
NTEP
Measurement Canada

*UL is only applicable to 882IS I/O and battery charger